JHT NetFiber | MTP/MPO Solutions

MTP/MPO Trunk Cables for High-Density Data Center Links

Pre-terminated multifiber assemblies used to connect cassettes, patch panels and direct-connect equipment across main, horizontal and equipment distribution areas.

OS2 / OM3 / OM4Male or FemalePolarity A / B / COptional Pulling Eye
What is an MTP/MPO trunk cable?

An MTP/MPO trunk cable is a factory-terminated multifiber backbone assembly. It consolidates multiple fibers into compact connectors so high-density links can be installed and reconfigured with less field termination.

Fiber typesOS2, OM3, OM4
Fiber count8-144 fibers*
ConnectorMTP or MPO
Jacket optionsLSZH / OFNR / OFNP
DocumentationConfirm per RFQ
Designed Around the Link

Specify the assembly as part of the complete cabling system.

The correct trunk cable depends on the transceiver interface, fiber architecture, polarity plan, enclosure layout, route and test requirements.

01

High-density backbone

Connect MTP/MPO cassettes and patch panels across structured data center distribution areas.

02

Direct-connect architecture

Build equipment links where the selected transceiver and network design support a direct multifiber interface.

03

Migration-ready planning

Coordinate fiber count, connector interface and polarity with current deployment and future migration requirements.

12-fiber multimode MTP MPO trunk cable
Pre-terminated trunk assemblyConnector, fiber type, polarity and length are defined for the project.
Why Trunk Cables

Reduce field termination while keeping configuration controlled.

Trunk assemblies arrive terminated for connection to compatible system components. The value is not only installation speed; it is the ability to define the complete assembly before it reaches the site.

Compact multifiber interfaceSupports dense patching and backbone routing.
Project-defined polarityChoose Method A, B or C as part of the end-to-end channel design.
Installation protection optionsOptional pulling-eye requirements can be reviewed for routed assemblies.
Configuration Matrix

Define these options before requesting a quote.

This table is the reusable decision core for JHT NetFiber product pages. Final availability and performance targets are confirmed against the selected construction.

Configuration fieldAvailable directionWhy it matters
Fiber typeOS2 singlemode; OM3 or OM4 multimodeMust match the optics, wavelength and link architecture.
Fiber countCommon supplied configurations span 8 to 144 fibers*Determines connector count, cable construction and panel density.
Connector platformMTP or MPO; male or femaleMust match adapters, cassettes, transceivers and pinned/unpinned interfaces.
PolarityMethod A, Method B or Method CControls transmit-to-receive mapping across the complete channel.
End-face / polishPC or APC where applicableDepends on fiber mode, connector platform and system design.
Cable jacketLSZH, OFNR or OFNP options listed in supplied documentationSelect according to installation environment and project requirements.
Length and breakoutProject-defined overall and breakout lengthsNeeds to match route, cabinet position and cable-management plan.
Loss grade and recordsStandard or low-loss target; documentation confirmed per RFQMust be evaluated against the channel loss budget and approval process.

*The supplied JHT source documents include 8-fiber and 12-144-fiber directions. Confirm the exact construction, fiber count and performance package for the requested assembly.

Product Views

Compare trunk-cable constructions and connector details.

RFQ Workflow

Turn the link requirement into a reviewable cable specification.

For the clearest quotation, share the architecture and constraints rather than only a generic part name.

Share the application

Data rate, optics, distribution areas, quantity and target route.

Define the interfaces

Fiber type, fiber count, MTP/MPO platform, gender and polish.

Confirm channel logic

Polarity method, cassette or direct-connect design and loss budget.

Agree approval evidence

Sample, labeling, packaging and applicable test documentation.

Quality Boundaries

Testing requirements should match the selected assembly.

JHT source specifications reference optical testing, polarity, end-face quality and mechanical/environmental test methods. The applicable values and report package must be confirmed for the quoted construction.

Optical performance targetDefine the insertion-loss and return-loss requirements for the link.
Polarity verificationConfirm the end-to-end mapping before production approval.
End-face inspectionAgree the applicable inspection criteria and documentation.
MPO connector detail for inspection and configuration review
Evidence, not generic claimsMatch the test and inspection package to the specific RFQ.
Buyer FAQ

Questions to resolve before ordering MTP/MPO trunk cables.

Short, complete answers support both procurement decisions and machine-readable product understanding.

What information should a trunk-cable RFQ include?

Include fiber type, fiber count, connector platform and gender, polarity, polish, jacket, overall length, breakout length, quantity, labeling, pulling-eye requirement and required test documentation.

How do I choose Method A, B or C polarity?

Choose polarity as part of the complete channel, including trunks, cassettes, patch cords and transceiver interfaces. Do not select a trunk polarity independently from the rest of the link.

Can JHT review a cable schedule or drawing?

Yes. A drawing or cable schedule can be used to clarify lengths, interfaces, polarity, labeling and system relationships before quotation.

Are low-loss assemblies available?

The supplied documentation includes standard and low-loss directions, but the target values and applicable construction should be confirmed for the specific RFQ and link loss budget.

When is a pulling eye useful?

A pulling eye can protect terminated ends during installation through pathways. Its need and dimensions should be reviewed against the actual route and installation method.

Configure the trunk cable around your link.

Send JHT NetFiber your drawing, cable schedule or project requirements for configuration review and quotation.

Request a Project Quote